Author: bugman Date: Thu Apr 10 17:42:39 2008 New Revision: 5570 URL: http://svn.gna.org/viewcvs/relax?rev=5570&view=rev Log: Bug fix for the AIC model selection between two diffusion tensors system test. The diffusion_tensor.init() fixed arg is now passed in as a bool. Modified: 1.3/test_suite/system_tests/model_selection.py Modified: 1.3/test_suite/system_tests/model_selection.py URL: http://svn.gna.org/viewcvs/relax/1.3/test_suite/system_tests/model_selection.py?rev=5570&r1=5569&r2=5570&view=diff ============================================================================== --- 1.3/test_suite/system_tests/model_selection.py (original) +++ 1.3/test_suite/system_tests/model_selection.py Thu Apr 10 17:42:39 2008 @@ -67,7 +67,7 @@ self.relax.interpreter._Relax_data.read('NOE', '500', 500.0 * 1e6, 'noe.500.out', dir=path) # Set the diffusion tensors. - self.relax.interpreter._Diffusion_tensor.init(tensors[i], fixed=0) + self.relax.interpreter._Diffusion_tensor.init(tensors[i], fixed=False) # Set some global stats. relax_data_store['sphere'].chi2 = 200