mailr8390 - in /branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b: ./ readme


Others Months | Index by Date | Thread Index
>>   [Date Prev] [Date Next] [Thread Prev] [Thread Next]

Header


Content

Posted by sebastien . morin . 1 on January 11, 2009 - 18:37:
Author: semor
Date: Sun Jan 11 18:37:42 2009
New Revision: 8390

URL: http://svn.gna.org/viewcvs/relax?rev=8390&view=rev
Log:
Created a directory for the data recorded at 800 MHz and put a readme file 
explaining its origin.

The readme file was copied using the command:
svn cp test_suite/shared_data/curve_fitting_disp/dataset_1-a/readme 
test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme
and was subsequently modified.


Added:
    branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/
    
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme
   (contents, props changed)
      - copied, changed from r8389, 
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-a/readme

Copied: 
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme
 (from r8389, 
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-a/readme)
URL: 
http://svn.gna.org/viewcvs/relax/branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme?p2=branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme&p1=branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-a/readme&r1=8389&r2=8390&rev=8390&view=diff
==============================================================================
--- 
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-a/readme
 (original)
+++ 
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme
 Sun Jan 11 18:37:42 2009
@@ -2,7 +2,7 @@
 The dataset contained in this folder was published in:
        Hansen, Vallurupalli & Kay, 2008, JPhysChemB, 112: 5898-5904.
 
-It contains the data recorded at 500 MHz using the improved pulse sequence 
with 1H CW decoupling
+It contains the data recorded at 800 MHz using the improved pulse sequence 
with 1H CW decoupling
 during the CPMG period.
 
 It was was friendly provided by Dr Flemming Hansen.

Propchange: 
branches/relax_disp/test_suite/shared_data/curve_fitting_disp/dataset_1-b/readme
------------------------------------------------------------------------------
    svn:mergeinfo = 




Related Messages


Powered by MHonArc, Updated Sun Jan 11 19:00:03 2009