mailr18258 - /trunk/test_suite/system_tests/n_state_model.py


Others Months | Index by Date | Thread Index
>>   [Date Prev] [Date Next] [Thread Prev] [Thread Next]

Header


Content

Posted by edward on January 22, 2013 - 11:11:
Author: bugman
Date: Tue Jan 22 11:11:01 2013
New Revision: 18258

URL: http://svn.gna.org/viewcvs/relax?rev=18258&view=rev
Log:
Fix for a recently introduced breakage of the 
N_state_model.test_mc_sim_failure system test.

Newton optimisation is now not allowed for optimising the paramagnetic centre 
position.


Modified:
    trunk/test_suite/system_tests/n_state_model.py

Modified: trunk/test_suite/system_tests/n_state_model.py
URL: 
http://svn.gna.org/viewcvs/relax/trunk/test_suite/system_tests/n_state_model.py?rev=18258&r1=18257&r2=18258&view=diff
==============================================================================
--- trunk/test_suite/system_tests/n_state_model.py (original)
+++ trunk/test_suite/system_tests/n_state_model.py Tue Jan 22 11:11:01 2013
@@ -482,7 +482,7 @@
         self.interpreter.monte_carlo.setup(number=3)
         self.interpreter.monte_carlo.create_data()
         self.interpreter.monte_carlo.initial_values()
-        self.interpreter.minimise('newton', constraints=False)
+        self.interpreter.minimise('simplex', constraints=False, max_iter=100)
         self.interpreter.monte_carlo.error_analysis()
 
 