mail[bug #20182] Window ordering broken when the sequence editor window is launched from a user function window.


Others Months | Index by Date | Thread Index
>>   [Date Prev] [Date Next] [Thread Prev] [Thread Next]

Header


Content

Posted by Edward d Auvergne on September 19, 2012 - 09:31:
URL:
  <http://gna.org/bugs/?20182>

                 Summary: Window ordering broken when the sequence editor
window is launched from a user function window.
                 Project: relax
            Submitted by: bugman
            Submitted on: Wed 19 Sep 2012 07:31:22 AM GMT
                Category: GUI
                Severity: 3 - Normal
                Priority: 5 - Normal
                  Status: None
                 Privacy: Public
             Assigned to: bugman
         Originator Name: 
        Originator Email: 
             Open/Closed: Open
         Discussion Lock: Any
                 Release: 2.1.0
        Operating System: All systems

    _______________________________________________________

Details:

When launching the sequence editor window from a sequence GUI element button
in the user function windows, the user function window will then be hidden
behind the main relax window.  The following steps reproduce the problem:

1.  Launch relax in GUI mode.
2.  Start a new NOE analysis.
3.  Click on the 'View->Spin viewer' menu item.
4.  Click on the 'Load spins' button.
5.  Select 'From a new PDB file' and click on 'Next'.
6.  Click on the sequence editor button on the far right of 'The read model'
field.
7.  Close the sequence editor window.

This will cause the main relax window to come to the front!




    _______________________________________________________

Reply to this item at:

  <http://gna.org/bugs/?20182>

_______________________________________________
  Message sent via/by Gna!
  http://gna.org/




Related Messages


Powered by MHonArc, Updated Wed Sep 19 10:20:09 2012