mailRe: Error in the manual


Others Months | Index by Date | Thread Index
>>   [Date Prev] [Date Next] [Thread Prev] [Thread Next]

Header


Content

Posted by Edward d'Auvergne on February 08, 2008 - 18:53:
Ah, I remember this one.  I changed the param_types values quite a
while ago, and the manual mustn't have been updated.  Would you like
to make the fix to the 1.3 line and then use svnmerge to port the
revision to the 1.2 line?  I'm just updating the svnmerge status of
the 1.2 line now.

Thanks,

Edward


On Feb 8, 2008 5:20 PM, Sebastien Morin <sebastien.morin.1@xxxxxxxxx> wrote:
Hi,

I found an error in the manual (from version 1.2.11).

page 136 :

=====================================
To select axially symmetric diffusion with a τm value of 8.5 ns, Dratio
of 1.1, θ value of 20
degrees, and φ value of 20 degrees, and assign it to the run 'm8', type:
relax> diffusion tensor('m8', (8.5e-9, 1.1, 20.0, 20.0), param types=1)
=====================================

The param_types should be 2.

Cheers,


Séb

--
Sebastien Morin
Etudiant au PhD en biochimie
Laboratoire de resonance magnetique nucleaire
Dr Stephane Gagne
CREFSIP (Universite Laval, Quebec, CANADA)
1-418-656-2131 #4530



_______________________________________________
relax (http://nmr-relax.com)

This is the relax-devel mailing list
relax-devel@xxxxxxx

To unsubscribe from this list, get a password
reminder, or change your subscription options,
visit the list information page at
https://mail.gna.org/listinfo/relax-devel