Hi Edward, I would be very glad to help out with that. My input data format is sparky peak lists (I export them from ccpnmr, but that doesn't make a difference)) The other part of the input data is a sequence file. I have problems loading a cyana generated structure. Not sure how it would behave with a structure outputted from ccpnmr or other programs. The structure is not in the pdb yet. I have two spin systems in there, but for testing, we can throw out the NHe from my tryptophan indole rings. For my test set, I can even calculate rates for inversion recovery and saturation recovery in ccpnmr. The reason that I changed to relax is, that the ccpnmr fitting routine is not robust enough for other sets. I'm very happy to send you real peak lists, or do they have to be synthetic for some reason? I could make real peak lists without tryptophan NHes if that helps. For synthetic peak lists, I have no experience in making those. But I think I could figure that out. I am attaching one set of relax that I did on this system with inversion recovery to the task and if this is what you are looking for, then I can also send you R1 values for inversion and saturation recovery fitting of this set in ccpnmr. I did have a problem with the experiment that I ran on relax though. It does converge and produces beautiful values, but the Rx values are negative. Which doesn't make any sense to me. The pattern is exactly as it should be, but the values are simply wrong. Do you have an idea what could be going on there? Best regards, Andras ________________________________________ From: edward.dauvergne@xxxxxxxxx [edward.dauvergne@xxxxxxxxx] On Behalf Of Edward d'Auvergne [edward@xxxxxxxxxxxxx] Sent: Wednesday, November 26, 2014 1:04 PM To: Andras Boeszoermenyi Cc: Boeszoermenyi, Andras; relax-devel@xxxxxxx Subject: Re: [sr #3195] Fitting of saturation recovery experiment Hi Andras, I was wondering if you were interested in helping out with the inversion-recovery task at https://gna.org/task/index.php?7415 ? What is your input data format, i.e. which peak list format are you using? Would it be possible to create synthetic peak lists containing with a single spin system whereby you have calculated what the peak intensities are based on your equation and some I0 and Rx parameter values? If this could be done, it could be added to the relax test suite directories and form the basis of an implementation. It could easily then be used to create a system test which checks that the fitting occurs as expected. Then implementing this should be easy. Cheers, Edward On 26 November 2014 at 16:59, Andras Boeszoermenyi <NO-REPLY.INVALID-ADDRESS@xxxxxxx> wrote:
URL: <http://gna.org/support/?3195> Summary: Fitting of saturation recovery experiment Project: relax Submitted by: andras Submitted on: Wed 26 Nov 2014 03:59:50 PM UTC Category: Feature request Priority: 5 - Normal Severity: 3 - Normal Status: None Assigned to: None Originator Email: Open/Closed: Open Discussion Lock: Any Operating System: Mac OS _______________________________________________________ Details: Hi, would it be possible to add an option to fit saturation recovery experiments to the existing 'exp' and 'inv' options in relax_fit? The formula should look like this: I(t) = I0*(1 - exp(−R1*t)) Best regards, Andras Boeszoermenyi _______________________________________________________ Reply to this item at: <http://gna.org/support/?3195> _______________________________________________ Message sent via/by Gna! http://gna.org/ _______________________________________________ relax (http://www.nmr-relax.com) This is the relax-devel mailing list relax-devel@xxxxxxx To unsubscribe from this list, get a password reminder, or change your subscription options, visit the list information page at https://mail.gna.org/listinfo/relax-devel