Dear relax users: I have a couple of questions regarding the relax program. First, the example scripts for model-free selection and optimization described in the relax manual utilize 15N relaxation data recorded at two fields. Does anyone have advice/experience in using relax to fit T1, T2 and NOE data recorded at only one field, particularly to models that include anisotropic global motion? Idealy, I would like to follow a local tm approach to model-free model selection and optimization, as recently described [d'Auvergne and Gooley (2008) J. Biomol. NMR 40, 107-119; ibid., 121-133], rather than a "diffusion seeded" approach. With data at one field, this analysis would be limted to models tm0 through tm3, and tm9. Are there relax scripts available for this type of an analysis with data at one field? Also, again using data from only one field, could one readily discern from the results of a local tm analysis if isotropic diffusion models are adequate? If adequate, this would allow fitting the data to models m0 through m5, and m9. A final question - have any facilites been added to relax (or planned) for fitting methyl 2H relaxation data? Thank you very much for your consideration. Any suggestions would be greatly appreciated. Keith Constantine |
begin:vcard fn:Keith L. Constantine, Ph.D. n:Constantine;Keith org:Bristol-Myers Squibb Company;Structural Biology and Modeling adr;quoted-printable;dom:;;P.O. Box 4000=0D=0A= Route 206 and Province Line Road=0D=0A= Building H, Room H.3112B;Princeton;NJ;08543 email;internet:keith.constantine@xxxxxxx title:Senior Research Investigator II tel;work:(609)252-6926 tel;fax:(609)252-6030 tel;home:(215)579-0276 x-mozilla-html:FALSE version:2.1 end:vcard