This is the model for 2-site exchange for off-resonance R1ρ-type data from Trott and Palmer (2002). It is selected by setting the model to `TP02'. The equation for the exchange process is
R1ρ = R1cos2θ + R1ρ'sin2θ + |
(11.76) |
in which
The equation is accurate only when populations are highly skewed with
pA pB.
And it is valid only for exchange processes which are not fast.
Note that this model has been superseded by the `TAP03' and `MP05' models.
The reference for this equation is:
More information about the TP02 model is available from:
The relax user manual (PDF), created 2024-06-08.