mailRe: [bug #22541] The R1 fit flag does not work in the GUI.


Others Months | Index by Date | Thread Index
>>   [Date Prev] [Date Next] [Thread Prev] [Thread Next]

Header


Content

Posted by Troels Emtekær Linnet on August 28, 2014 - 15:05:
I dont think the r1_fit flag is available in 'cdp', before analysis start.

Can that have something to do with it?

2014-08-28 15:03 GMT+02:00 Edward d  Auvergne
<NO-REPLY.INVALID-ADDRESS@xxxxxxx>:
Follow-up Comment #1, bug #22541 (project relax):

I can replicate this.  However in the log messages I see:

"""
----------------------------------------
- R1 parameter optimisation activation -
----------------------------------------


relax> relax_disp.r1_fit(fit=True)
"""

Therefore the R1 fit flag is working in the GUI and is being passed 
correctly
into the auto-analysis.  The problem is therefore not in the GUI itself.

    _______________________________________________________

Reply to this item at:

  <http://gna.org/bugs/?22541>